SEER Inquiry System - Report
Produced: 11/24/2024 6:08 PM
Question 20051015
Inquiry Details
References:
2004 SEER Manual, C-473. Appendix C
Question:
Priorities/CS Tumor Size--Breast: What is the priority order used in coding tumor size for this site when there is a larger 2 cm lesion noted on the PET scan and smaller sizes described in the pathology report as two malignant masses one measuring 0.8 cm and the second measuring 1.0 cm per the GROSS?
Discussion:
Answer:
This answer was provided in the context of CSv1 coding guidelines. The response may not be used after your registry database has been converted to CSv2.Code CS Tumor Size as 1.0 cm. The pathology report is the highest priority source for coding tumor size. When multiple tumors are present, code the size of the largest tumor.
Cancer Site Category:
Breast
Data Item Category:
N/A
Other Category:
N/A
Year:
2005