EOD-Size of Primary Tumor--Prostate: Should the size of tumor be recorded as 001 (focus) or the actual size when both are stated? See Discussion.
The pathology report from a TURP identifies a 3-mm focus of adenocarcinoma.
For cases diagnosed 1998-2003, code the EOD-Size of Primary Tumor field to 003 [3 mm]. The rule that says to code a focus or foci of tumor as 001 was developed for use when no tumor size is given.
EOD-Size of Primary Tumor--Prostate: Is this field coded to the size of a hypoechoic mass identified on a TRUS when there is no tumor size from the prostatectomy specimen?
For cases diagnosed 1998-2003: Ultrasound measurement of a malignancy can be used to code EOD-Size of Primary Tumor. Information on tumor size taken from imaging/radiographic techniques has low priority, just above physical examination.
EOD-Size of Primary Tumor--Prostate: If you only have a biopsy and not a resection of the primary site, can you code the size of the prostate nodule demonstrated on digital rectal exam? See discussion.
Example 1: Digital rectal exam reveals 1 cm left side prostate nodule. TRUS-guided biopsy of left side of prostate shows adenocarcinoma. Right side biopsy is negative. Is size coded to 010 or 999?
Example 2: Digital rectal exam reveals 1 cm left side prostate nodule. Bone scan was positive for metastatic disease. Is size coded to 010 or 999?
For cases diagnosed 1998-2003:
You need path confirmation that a malignancy exists in the prostate before you can code the size of the nodule seen clinically.
Example 1: Code the EOD-Size of Primary Tumor to 010 [1 cm], because the nodule in the prostate is confirmed as cancer by needle biopsy.
Example 2: Code the EOD-Size of Primary Tumor to 999 because there was no pathologic confirmation of malignancy.
EOD-Size of Primary Tumor--Melanoma: How do you code tumor size for a melanoma diagnosed by a positive lymph node biopsy when the primary site is coded C44.9 because no primary site was identified? See discussion.
Should the size be 000 because no primary was found or 999 for unknown?
For cases diagnosed 1998-2003:
Code the EOD-Size of Primary Tumor field to 000 [No mass; no tumor found] when primary site is coded to C449.
EOD-Size of Primary Tumor--Lung: Can tumor size of 002 [Malignant cells present in bronchopulmonary secretions] be used when there is a lung mass seen but the diagnosis is from a positive bronchopulmonary secretion?
For cases diagnosed 1998-2003:
EOD-Size of Primary Tumor code 002 [Malignant cells present in bronchopulmonary secretions] is used only when there is no visible primary lung tumor and bronchopulmonary secretions are positive for lung malignancy.
Even if the diagnosis was made by cytology of broncho-pulmonary secretions, if there is a visible mass, code the size of the mass if known, code 999 if size is unknown.
EOD-Size of Primary Tumor--Corpus Uteri: If both the width and depth of the tumor are provided, do we code the largest dimension in the tumor size field? If the width dimension is not provided, can we code the depth of the tumor in the tumor size field? See discussion.
Example: An endometrial primary is described as having, "a soft lobulated tumor diffusely involving the entire endometrium, extending 2.0 cm into the myometrium."
For cases diagnosed 1998-2003:
Code the EOD-Size of Primary Tumor field to 999 [unknown] for this case because this field is supposed to reflect the dimension for tumor width and not tumor depth. Tumor depth is coded in the EOD-Extension field.
EOD-Size of Primary Tumor--Colon: When an adenocarcinoma is stated to be arising in an adenoma and the "tumor size" stated in the final pathologic diagnosis is the same size as the mass described in the gross description, should we assume that the entire polyp has been totally/near totally replaced by tumor and code the tumor size stated in the final path diagnosis?
For cases diagnosed 1998-2003:
Code the EOD-Size of Primary Tumor field as stated by the pathologist in the final pathologic diagnosis. If the size of the tumor is the same as the size of the polyp, assume the polyp was completely replaced by tumor.
EOD-Size of Primary Tumor--Cervix: When both a depth and diameter of the tumor are provided and the description of the diameter is provided in a range, how do you code the size of the primary tumor? See discussion.
Path states "microscopic focus of endocervical glands considered invasive adenoca...maximum depth of that focus measures approximately 2 mm. Maximum diameter of that focus measures 3-4 mm."
What size would be coded for this case: 999, 002, 003, or 004?
Code the EOD-Size of Primary Tumor field to 004 [4 mm]. Code the diameter dimension in the EOD-Size of Primary Tumor field and the depth dimension iin the EOD-Extension field. Code the largest number associated if a range is provided for the diameter of the invasive tumor.
If the size of the diameter had not been mentioned, the EOD-Size of Primary Tumor field would have been coded to 001 [microscopic focus or foci only], which ignores the size associated with the depth dimension of the tumor.
EOD-Size of Primary Tumor--Breast: When the pathology report does not specify dimensions for the invasive component, how is tumor size coded? See discussion.
In some cases the tumor has both invasive and in situ components. The pathologist sometimes does not report the size for the invasive portion of the tumor. In most cases, the invasive portion is described as a percentage of the tumor mass.
From January 1, 1998 and forward: Follow the Revised Breast EOD instructions. If the size of the invasive component is not given, record the size of the entire tumor in the EOD-Size of Primary Tumor field. Assign the appropriate EOD-Extension code for the situation.
EOD-Size of Primary Tumor--Breast: The path report provides a size for both the Paget disease and the underlying intraductal component in the breast. Should we assume the Paget disease to be invasive and code the size of the primary tumor to that invasive component? See discussion.
For example, path diagnosis for resection gave the size of the Paget disease as 1 mm and the size of the underlying intraductal tumor as 4 cm. Should size for this breast case be coded to 040 or 003, less than 3 mm.
For cases diagnosed 1998-2003:
Code the EOD-Size of Primary Tumor field to 040 [4 cm], the size of the larger underlying intraductal tumor. Paget disease is classified according to the size of the underlying in situ or invasive tumor. Paget with an underlying in situ tumor is staged as in situ to match the AJCC classification of this disease process.