CS Size of Tumor/CS Extension--Brain and CNS: How should these fields be coded for benign CNS tumors?
This answer was provided in the context of CSv1 coding guidelines. The response may not be used after your registry database has been converted to CSv2.Code CS Extension as 05 [Benign or borderline brain tumors]. Code the size of the tumor if specified. Otherwise code CS Tumor Size as 999 for benign CNS tumors.
CS Eval--Ovary: How is CS Mets Eval coded when the patient has positive pleural effusion confirmed by cytology?
This answer was provided in the context of CSv1 coding guidelines. The response may not be used after your registry database has been converted to CSv2.Code CS Mets Eval for the example above 3 [path exam of metastatic tissue] assuming there has been no pre-treatment. Positive cytology is required for confirmation of pleural effusion for an ovarian primary.
CS Tumor Size--Melanoma: How is this field coded when a smaller invasive and a larger in situ melanoma are reported as a single primary? See Discussion.
Patient has a 1.2 cm lesion right upper arm with a diagnosis of melanoma in situ. A second lesion on right wrist, 0.5 cm mole, has a diagnosis malignant melanoma, Breslow's 0.78, Clark's level III.
According to the 2007 MP/H rules, this is a single primary. Because the larger lesion is completely in situ, do you ignore it altogether and go with the smaller, invasive lesion? SEER Program Manual 2007, page 127, rule 4.l, states that when two lesions are reported as a single primary, code the size of the larger lesion, which in this case would be the in situ.
This answer was provided in the context of CSv1 coding guidelines. The response may not be used after your registry database has been converted to CSv2.Code CS Tumor Size as 005 (0.5 cm). Code CS Tumor Size based on the invasive lesion.
Use the data items "Multiplicity Counter" and "Type of Multiple Tumors Reported as One Primary" to document that there are two tumors present, in situ and invasive.
Priorities/CS Tumor Size--Breast: What is the priority order used in coding tumor size for this site when there is a larger 2 cm lesion noted on the PET scan and smaller sizes described in the pathology report as two malignant masses one measuring 0.8 cm and the second measuring 1.0 cm per the GROSS?
This answer was provided in the context of CSv1 coding guidelines. The response may not be used after your registry database has been converted to CSv2.Code CS Tumor Size as 1.0 cm. The pathology report is the highest priority source for coding tumor size. When multiple tumors are present, code the size of the largest tumor.
CS Tumor Size: Is a 5.5 mm tumor coded as 005 or 006? See Discussion.
We interpret the CS Manual general instructions to indicate to ONLY round up to 001 when the tumor size is stated to be 0.1 to 0.9mm.
This answer was provided in the context of CSv1 coding guidelines. The response may not be used after your registry database has been converted to CSv2.Code CS tumor size 006. Because only whole numbers in mm can be collected, basic mathematical principles are used for rounding; 1-4 round down, 5-9 round up.
CS Tumor Size/CS Site Specific Factor--Breast: When tumor size is unknown, but it is known that both in situ and invasive components are present, how should CS Tumor Size and SSF6 be coded? See Discussion.
We coded CS Tumor Size 990 and SSF 6 to 060 for a case in which no tumor size was mentioned and the breast core biopsy identified microinvasive infiltrating lobular carcinoma and lobular carcinoma insitu. The lumpectomy identified no residual tumor. SEER edit 218 states we must have CS Tumor Size as 999 if the CS SSF 6 is 060. Yet the tumor size code of 990 (Microinvasion; microscopic focus or foci only, no size given; described as less than 1 mm) would more accurately reflect this case. Even in a situation where there was microinvasion described as less than 1mm, the edit will not allow one to code CS Tumor Size to 990 with the CS SSF 6 as 060. Should these types of cases have CS Tumor Size coded 999 or should the edit be adjusted to allow for this combination?
This answer was provided in the context of CSv1 coding guidelines. The response may not be used after your registry database has been converted to CSv2.Code CS tumor size 990 [Microinvasion; microscopic focus or foci only, no size given; described as less than 1 mm] and CS SSF6 050 [Invasive and in situ components present, size of entire tumor coded in CS Tumor Size because size of invasive component not stated AND proportions of in situ and invasive not known].
This combination of codes captures the information available for this case.
CS Tumor Size--Ovary: Can the size of a tumor mass shadow seen on a CT scan be used to code CS Tumor Size? See Discussion.
Ovarian primary: No surgery performed. CT abd/pelvis states "Bilateral pleural effusions, ascites. Right appendix region with tumor mass shadow 3 x 8 x 3.9cm"
This answer was provided in the context of CSv1 coding guidelines. The response may not be used after your registry database has been converted to CSv2.Code CS tumor size 999 [Unknown; size not stated]. The size of the tumor is not known in this case.
Note that tumor size is not used for AJCC staging for ovary.
CS Site Specific Factor--Lymphoma: Can the term "intermediate risk" be used to code IPI score? See Discussion.
Patient has Hodgkin disease. The physician states that the patient has bulky stage IIA intermediate risk disease. Is the term "risk" another way of stating IPI score? If so, how would intermediate risk be coded?
This answer was provided in the context of CSv1 coding guidelines. The response may not be used after your registry database has been converted to CSv2.Code SSF 3 for lymphoma based on the IPI score stated in the record. Do not attempt to interpret statements or terms in order to assign a code to SSF 3. If no further information is available for this case, code SSF 3 999 [Unknown].
CS Site Specific Factor 6--Breast: Should we assume that the invasive portion of the tumor is being referred to when a pathologist provides only a single tumor size but includes both invasive and in situ descriptors when discussing the size of that tumor? See Discussion.
There seems to be subtle variations in wording and punctuation in these cases. Would these three examples be coded the same way?
Examples:
"invasive ductal carcinoma 2.0 cm, DCIS present"
"2 cm invasive ductal carcinoma with DCIS present"
"invasive ductal carcinoma 2.0 cm. DCIS present"
This answer was provided in the context of CSv1 coding guidelines. The response may not be used after your registry database has been converted to CSv2.Code SSF6 050 [invasive and insitu components present, entire size coded in CS TS, size of invasive not stated, proportion invasive and insitu not known] when the size of the invasive portion is not provided and clarification is not available.
If possible, obtain clarification from the pathologist for phrases like these and document in a text field. For example, a pathologist may confirm that when he/she states "invasive ductal carcinoma 2.0 cm, DCIS present" the size of the invasive portion is 2 cm. If so, code CS tumor size 020 and SSF6 020 and explain in a text field.
CS Site Specific Factor--Breast: How is SSF6 coded when CS tumor size is coded from a clinical report, not from pathology? See Discussion.
A breast ultrasound displays a 2 cm tumor. Core biopsy diagnosis is lobular carcinoma in situ. No further record for patient. Tumor size coded to 020. Should SSF 6 be coded to 010 "Entire tumor reported as in situ (no invasive component reported)" because it was pathologically confirmed, or to 888 because size was coded based on a clinical exam - the ultrasound?
This answer was provided in the context of CSv1 coding guidelines. The response may not be used after your registry database has been converted to CSv2.Code SSF6 888 [Clinical tumor size coded]. When the size recorded in CS Tumor Size is not determined pathologically, 888 must be coded in SSF6. Note: The code in SSF 6 pertains to pathologic tumor size. It describes the relationship of invasive and in situ tumor in the tumor size coded.